<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22268</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Failed to grab slipsheet from bottom of upper plate. Check next
plate for scratches
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Operator probably forgot to put a slipsheet between stacks of
plates, or slipsheet was blown to the back of the bay. Resume will
continue the pick as if it had grabbed a slipsheet, but it is likely
that the plate will have been damaged.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume, but inspect the next plate carefully for scraches.
</text></DescriptionText>
</OperatorAction>
<Cause>
ssvth wrong. missing slipsheet between plates.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/val_cal_ssvth.xml</LinkAddress><LinkTitle>NVS: val ssvth</LinkTitle></Link>
<Link><LinkAddress>../commands/cal_ssvth.xml</LinkAddress><LinkTitle>Command: cal ssvth</LinkTitle></Link>
<Link><LinkAddress>../commands/cal_picker.xml</LinkAddress><LinkTitle>Command: cal picker</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:02 2008 PST
</Updated>
<Links>
</Links>
</Error>